Domestic Systems

Panther Alert


pan_alert[1]


The Panther Alert is a four zone gas detection control panel for use with all gas detectors in our range.


If gas is detected it will automatically shut the gas solenoid valve and stop the gas supply.

Panther Cub


PantherCub – Gas Monitoring and Automatic Gas Cut off
PantherCub – Kitchens/Residential Heating

panthercub[1]


Specifications (2 Channel Monitor)


Model : PA02
Supply Voltage : 240 V AC
Operating Voltage : +12DC
Visual Indicators
Green LED : Power Supply
Red LED : Alarm Status
Key Switch Operation : Enable – Reset (key removable only in Enable position)
Size : 120mm x 70mm x 45mm
Detectors : No limit to numbers/models per zone


Product Order Code
PantherCub Monitor 240V PA02
Natural Gas Detector 240V 610
Carbon Monoxide Detector 240V 710
Heat Detector 240V 609
Emergency Stop Button EM1

Panther Control


Specifications
Manual & Monitoring Control System for gas or water services in Laboratories & Workshops

panthercontrol[1]


Supply Voltage : 240 V AC
Key-reset for security
Visual Indicators
Green : Power On
Red : Water/Gas On
Push Button Control
Internally Fused
Facility for Emergency stop Button input
Facility for Gas/Heat Detector input
To be used with gas or water solenoid valves
Concealed torx safety screwed top
125mm x 73 mm x 45mm
Wall mounted


Product Order Code
Panther Control Unit PA01
Emergency Stop Button EM1
Natural Gas detector 610
Gas & Water Solenoid Valves See price list

Panther 300 – Interlock System

<style=”text-align: justify;”>
pan_alert[1]

75-sm[1]

The Panther 300 is now discontinued, we recommend you use the Panther V75 Gas Safety Interlock System shown here to the right.

CO2 Monitoring & Alarm System for Cellars & Confined Spaces

carbon_dioxide_schematic[1]


Carbon Dioxide Risks


Carbon Dioxide (CO2) is used extensively in the pub and catering industries. Leaks from equipment can build up in confined areas. It also can build up in other industries where it can occur including chemical industries, plant growing and fermentation.


Build up of CO2 can be very dangerous in confined spaces resulting in death in extreme cases. Because it is odourless and colourless a person cannot easily detect an increase in CO2.


Legislation


The Confined Spaces Regulations of 1997 forces employers to be responsible for the health and safety of any employees who could be at risk of CO2.


How to protect from CO2


The CO2 Detector protects by: Detecting the presence of increasing CO2 long before it reaches unsafe levels. Sounding an alarm when a leak is detected. Triggering remote alarms to warn people not to enter the room. Switching on ventilation.


Product Order Code


Carbon Dioxide Detector 360
Carbon Dioxide Remote Alarm 365


Gas Shut off valve set NAT Gas or LPG Domestic


Domestic installations e.g. gas cooker, gas fire etc


The installation of a gas isolation valve and gas detector can provide piece of mind to family and carers of elderly, infirm or at-risk persons. A gas leak from a gas hob, oven or gas fire can be made safe automatically before dangerously high levels of gas occur. The gas would not be re-instated until the manual gas isolation valve has been reset by a responsible person. This can be linked with a sounder and beacon to alert the user and carers that gas has been isolated.


detector[1]

valve[1]


Safety Kit includes a LPG gas detectors (RGG) and Solenoid Valve NO connection 1/2″
Main characteristic:

•Gas Detector Power Supply: 230V AC
•Solenoid Valve Power Supply: 230V AC
•Colour: White
•Solenoid Valve Connection: 1/2″



detector[1]

valve[1]


Safety Kit includes a LPG gas detectors (RGG) and Solenoid Valve NO connection 3/4″
Main characteristic:

•Gas Detector Power Supply: 230V AC
•Solenoid Valve Power Supply: 230V AC
•Colour: White
•Solenoid Valve Connection: 1/2″


detector[1]

valve[1]


Safety Kit includes a Methane gas detector (RGM) and Solenoid Valve NO connection 1/2″
Main characteristic:

•Gas Detector Power Supply: 230V AC
•Solenoid Valve Power Supply: 230V AC
•Colour: White
•Solenoid Valve Connection: 1/2″


detector[1]

valve[1]


Safety Kit includes a Methane gas detector (RGM) and a Solenoid Valve NO connection 3/4″
Main characteristic:

•Gas Detector Power Supply: 230V AC
•Solenoid Valve Power Supply: 230V AC
•Colour: White
•Solenoid Valve Connection: 1/2″


Leak Detection


Leak Detection Systems for Water, Hydrocarbons, Refrigerants and Chemicals


valve[1]


Leak detection systems can be used in operating theatres, control rooms, telecoms equipment, archives stores, libraries, luxury homes, computer facilities, plant rooms, fuel storage facilities etc. A leak can be detected and prompt action taken to avoid expensive loss of stored products and environmental damage being caused.


Things to know.
1.Area requiring coverage (comms room, tea point etc) if no drawings available room dimensions.
2.Raised or Solid Floor.
3.Location of pipework (if any) at high and low level.
4.If pipework is at high level is it covered by drip trays.
5.Is BMS (Building Maintenance System) interface required.
6.Potential location of the Control Panel.
7.Is there any possibility of the system being expanded in the future.


Data Sheets
TT1000_Data_Sheet_H53870_10_96
AT-WM_Water_Monitor_Datasheet
AT-WM1_Water_Monitor_System_Technical_Data_(50-200mm_meters)
AT-SZA_Data_Sheet_H9150_13
AT-PROBE-TS-M_Data_Sheet_H9030_7
AT-OPSEN_Operating_Principles
AT-OPSEN_Data_Sheet_H9140_10
AT-MZA_Data_Sheet_H9160_21

 

Contact Us:

Sales Enquiries: sales@panthergasdirect.com
Accounts Information: accounts@panthergasdirect.com

Full Postal Address:


Panthergas Direct Ltd
Unit D4 Seedbed Business Centre
Vanguard Way
Shoeburyness
Essex. SS3 9QY

Telephone: 01702 384038

 
Translate »